VM-VDI2230-BOLT-004: Annex B, Example B4

Annex B, Example B4 of VDI 2230 Part 1:2015: the necked-down bolt of a connecting-rod bearing cap (eccentric clamping and eccentric loading, angle-controlled tightening beyond the elastic limit), used to check the clamp loads, resilience, embedding, preload, surface pressure and slipping results of the VDI 2230-1 single-bolt calculator point by point.

VM-VDI2230-BOLT-008: Connecting-rod bolt, eccentric clamping and loading

The connecting-rod necked-down bolt of a textbook worked example (eccentric clamping and eccentric loading, angle-controlled tightening), used to check the clamp loads, resilience, preload, surface pressure and fatigue results of the VDI 2230-1 single-bolt calculator point by point.

VDI 2230 (010): Eccentric Load and Bending-Moment Effect

Explains eccentric clamping and eccentric loading in VDI 2230: the two eccentricity parameters, the corrected resiliences, the load factor, the substitutional moment of inertia, and the clamp load needed to prevent opening.